Your browser doesn't support javascript.
loading
Evaluation of Changes in Tear Film Lipid Layer Thickness Using Ocular Surface Interferometer after Artificial Tear Application
Journal of the Korean Ophthalmological Society ; : 1857-1865, 2016.
Article in Korean | WPRIM | ID: wpr-124585
ABSTRACT

PURPOSE:

The changes in tear film lipid layer thickness (LLT) after artificial tears application using LipiView®II interferometer were assessed.

METHODS:

We performed a prospective study of patients with dry eye disease. All subjects underwent measurement of tear film break-up time, Schirmer test, ocular surface staining, meibomian gland evaluation, and subjective score assessment using the Ocular Surface Disease Index. All subjects were randomly assigned to 1 of 3 groups using table of random numbers (group 1, sodium hyaluronate [HA] 0.1% eye drops without preservatives; group 2, HA 0.3% eye drops without preservatives and group 3, HA 0.1% with benzalkonium chloride 0.003%). LLT was measured before, immediately after and 1 hr, 3 hrs, and 6 hrs after artificial tears application. Additionally, the patients were divided into 2 subgroups depending on the presence of meibomian gland dysfunction (MGD) and further evaluated.

RESULTS:

Significant change in LLT was observed at 3 hrs after artificial tears instillation. LLT in groups 1 and 2 showed significant changes over time (p < 0.01 and p < 0.01, respectively). However, LLT in group 3 showed no change. LLT was unchanged in patients without MGD. Conversely, in MGD patients, a significant difference in LLT between groups 1 and 2 was observed immediately after and 1 hr and 3 hrs after instillation of artificial tears (p = 0.04, p < 0.01 and p = 0.02, respectively) but not at 6 hrs. However, no significant difference in LLT between groups 1 and 3 was observed in MGD patients.

CONCLUSIONS:

LLT after instillation of artificial tears measured using LipiView®II interferometer was affected by artificial tear concentration and presence of preservatives. Additionally, the presence of MGD can impact the pattern of LLT changes induced by artificial tear instillation. Therefore, LLT measurements using LipiView®II interferometer require at least a 6-hrs interval after use of eye drops, especially for patients with MGD or using artificial tears with preservatives.
Subject(s)

Full text: Available Index: WPRIM (Western Pacific) Main subject: Ophthalmic Solutions / Tears / Benzalkonium Compounds / Prospective Studies / Eye Diseases / Lubricant Eye Drops / Hyaluronic Acid / Meibomian Glands Type of study: Observational study Limits: Humans Language: Korean Journal: Journal of the Korean Ophthalmological Society Year: 2016 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Main subject: Ophthalmic Solutions / Tears / Benzalkonium Compounds / Prospective Studies / Eye Diseases / Lubricant Eye Drops / Hyaluronic Acid / Meibomian Glands Type of study: Observational study Limits: Humans Language: Korean Journal: Journal of the Korean Ophthalmological Society Year: 2016 Type: Article