Total Body Irradiation Technique: Basic Data Measurements and In Vivo Dosimetry / 대한치료방사선과학회지
Journal of the Korean Society for Therapeutic Radiology
; : 219-224, 1994.
Article
in Ko
| WPRIM
| ID: wpr-125378
Responsible library:
WPRO
ABSTRACT
This paper describes the basic date measurements for total body irradiation with 6 Mv photon beam including compensators designs. The technique uses bilateral opposing field with tissue compensators for the head, neck, lungs, and legs from the hip to toes. In vivo dosimetry was carried out for determining absorbed dose at various regions in 7 patients using diode detectors (MULTIDOSE, Model 9310, MULTIDATA Co., USA). As a results, the dose uniformity of+/-3.5%(generally, within+/-10%) can be achieved with our total body irradiation technique.
Key words
Full text:
1
Index:
WPRIM
Main subject:
Toes
/
Whole-Body Irradiation
/
Head
/
Hip
/
Leg
/
Lung
/
Neck
Limits:
Humans
Language:
Ko
Journal:
Journal of the Korean Society for Therapeutic Radiology
Year:
1994
Type: