Central Corneal Thickness in Korean Subjects with Primary Angle-Closure Glaucoma
Journal of the Korean Ophthalmological Society
; : 402-407, 2014.
Article
in Ko
| WPRIM
| ID: wpr-127406
Responsible library:
WPRO
ABSTRACT
PURPOSE: To compare the central corneal thickness (CCT) in eyes of Korean subjects with primary angle-closure glaucoma (PACG) to other patients with glaucoma and control subjects. METHODS: Medical records of patients who underwent examination for glaucoma and pre-operative examination for cataract surgery between March 2009 and August 2012 in our clinic were reviewed. CCT was compared in normal control eyes, primary open angle glaucoma (POAG) eyes and normal tension glaucoma (NTG) eyes. RESULTS: The mean CCT of POAG eyes was significantly larger than that of normal control eyes, NTG eyes and PACG eyes (p = 0.027, 0.009 and 0.008, respectively). There was no significant difference in mean CCT between normal control eyes, NTG eyes or PACG eyes. CONCLUSIONS: PACG eyes had a CCT similar to that of NTG or normal eyes in Korean subjects.
Key words
Full text:
1
Index:
WPRIM
Main subject:
Cataract
/
Glaucoma, Angle-Closure
/
Glaucoma
/
Glaucoma, Open-Angle
/
Medical Records
/
Low Tension Glaucoma
Limits:
Humans
Language:
Ko
Journal:
Journal of the Korean Ophthalmological Society
Year:
2014
Type:
Article