Use of a Valved-Conduit for Exclusion of the Infected Portion in the Prosthetic Pulmonary Valve Endocarditis
The Korean Journal of Thoracic and Cardiovascular Surgery
;
: 208-211, 2013.
Article
in English
| WPRIM
| ID: wpr-129692
ABSTRACT
A 51-year-old male was admitted to the hospital with complaints of fever and hemoptysis. After evaluation of the fever focus, he was diagnosed with pulmonary valve infective endocarditis. Thus pulmonary valve replacement and antibiotics therapy were performed and discharged. He was brought to the emergency unit presenting with a high fever (>39degrees C) and general weakness 6 months after the initial operation. The echocardiography revealed prosthetic pulmonary valve endocarditis. Therefore, redo-pulmonary valve replacement using valved conduit was performed in the Rastelli fashion because of the risk of pulmonary arterial wall injury and recurrent endocarditis from the remnant inflammatory tissue. We report here on the successful surgical treatment of prosthetic pulmonary valve endocarditis with an alternative surgical method.
Full text:
Available
Index:
WPRIM (Western Pacific)
Main subject:
Pulmonary Valve
/
Echocardiography
/
Emergencies
/
Endocarditis
/
Fever
/
Hemoptysis
/
Anti-Bacterial Agents
Limits:
Humans
/
Male
Language:
English
Journal:
The Korean Journal of Thoracic and Cardiovascular Surgery
Year:
2013
Type:
Article
Similar
MEDLINE
...
LILACS
LIS