Two Cases of Catheter Ablation of Atrioventricular Reentrant Tachycardia by Right Septal Bypass Tract Mapped Using Multielectrode Basket Catheter
Korean Circulation Journal ; : 1448-1454, 2000.
Article in Korean | WPRIM | ID: wpr-13049
ABSTRACT
It has been known that right side bypass tract ablation is more difficult and has higher recurrence rate than that of left side bypass tract, and often associated with atrioventricular block in patients with septal bypass tract. Multielectrode basket catheter (MBC) allows simultaneous rapid acquisition of numerous electrical signals generated by a selected surface area or volume of myocardium. We experienced two cases of successful catheter ablation of atrioventricular reentrant tachycardia by right septal bypass tract which were mapped by MBC with greater ease.