Aorto-Esophageal Fistula Complicated by Esophageal Metalic Stent: A case report / 대한흉부외과학회지
The Korean Journal of Thoracic and Cardiovascular Surgery
;
: 479-482, 2002.
Article
in Korean
| WPRIM
| ID: wpr-13660
ABSTRACT
Aortoesophageal fistula induced by endoesophageal stent is rare;however,it is usually a fatal disorder,with few survivors reported.We report a case of a 32-year old female with aortoesophaeal fistula after insertion of the esophageal stent in esophageal lye stricture who was successfully diagnosed with endoscopy and treated in a two-stage operation.In the first stage,we performed esophagectomy,primary repair of the fistula site in the descending thoracic aorta,and feeding gastrostomy.After the patient recovered well postoperatively,a retrosternal interposition of the right colon and cervical esophago-colo-grastostomy were performed,to re-establish the gastrointestinal tract.
Full text:
Available
Index:
WPRIM (Western Pacific)
Main subject:
Stents
/
Survivors
/
Colon
/
Constriction, Pathologic
/
Gastrointestinal Tract
/
Endoscopy
/
Fistula
/
Lye
Limits:
Adult
/
Female
/
Humans
Language:
Korean
Journal:
The Korean Journal of Thoracic and Cardiovascular Surgery
Year:
2002
Type:
Article
Similar
MEDLINE
...
LILACS
LIS