Two cases of small bowel herniation through 5 mm trocar site following removal of drains after gynecologic laparoscopy / 대한산부인과학회지
Korean Journal of Obstetrics and Gynecology
;
: 129-132, 2009.
Article
in Korean
| WPRIM
| ID: wpr-143766
ABSTRACT
After laparoscopic surgery, most cases of incisional hernia occur when a trocar greater than 10 mm is used and this rarely occurs when a 5 mm trocar is used. We recently experienced two cases of incisional herniation at a 5 mm port site in connection with withdrawal of the drain after laparoscopic procedure.