Your browser doesn't support javascript.
loading
Interrupted aortic arch diagnosed with loss of femoral pulse in a patient undergoing patent ductus arteriosus ligation: A case report / 대한마취과학회지
Korean Journal of Anesthesiology ; : 477-479, 2010.
Article in English | WPRIM | ID: wpr-145227
ABSTRACT
A 12-year-old boy with ventricular septal defect and patent ductus arteriosus was presented to the operating room. Upon clamping the patent ductus arteriosus, the femoral arterial pressure curve was lost; however, it returned upon unclamping. Upon further dissection, an interrupted aortic arch was found between the left subclavian artery and patent ductus arteriosus. The surgery was discontinued for further evaluation.
Subject(s)

Full text: Available Index: WPRIM (Western Pacific) Main subject: Operating Rooms / Aorta, Thoracic / Subclavian Artery / Blood Pressure / Constriction / Ductus Arteriosus, Patent / Femoral Artery / Arterial Pressure / Heart Septal Defects, Ventricular Type of study: Diagnostic study Limits: Child / Humans Language: English Journal: Korean Journal of Anesthesiology Year: 2010 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Main subject: Operating Rooms / Aorta, Thoracic / Subclavian Artery / Blood Pressure / Constriction / Ductus Arteriosus, Patent / Femoral Artery / Arterial Pressure / Heart Septal Defects, Ventricular Type of study: Diagnostic study Limits: Child / Humans Language: English Journal: Korean Journal of Anesthesiology Year: 2010 Type: Article