Your browser doesn't support javascript.
loading
Measurement of Opening and Closing Angles of Aortic Valve Prostheses In Vivo Using Dual-Source Computed Tomography: Comparison with Those of Manufacturers' in 10 Different Types
Korean Journal of Radiology ; : 1012-1023, 2015.
Article in English | WPRIM | ID: wpr-163302
ABSTRACT

OBJECTIVE:

The aims of this study were to compare opening and closing angles of normally functioning mechanical aortic valves measured on dual-source computed tomography (CT) with the manufacturers' values and to compare CT-measured opening angles according to valve function. MATERIALS AND

METHODS:

A total of 140 patients with 10 different types of mechanical aortic valves, who underwent dual-source cardiac CT, were included. Opening and closing angles were measured on CT images. Agreement between angles in normally functioning valves and the manufacturer values was assessed using the interclass coefficient and the Bland-Altman method. CT-measured opening angles were compared between normal functioning valves and suspected dysfunctioning valves.

RESULTS:

The CT-measured opening angles of normally functioning valves and manufacturers' values showed excellent agreement for seven valve types (intraclass coefficient [ICC], 0.977; 95% confidence interval [CI], 0.962-0.987). The mean differences in opening angles between the CT measurements and the manufacturers' values were 1.2degrees in seven types of valves, 11.0degrees in On-X valves, and 15.5degrees in ATS valves. The manufacturers' closing angles and those measured by CT showed excellent agreement for all valve types (ICC, 0.953; 95% CI, 0.920-0.972). Among valves with suspected dysfunction, those with limitation of motion (LOM) and an increased pressure gradient (PG) had smaller opening angles than those with LOM only (p < 0.05).

CONCLUSION:

Dual-source cardiac CT accurately measures opening and closing angles in most types of mechanical aortic valves, compared with the manufacturers' values. Opening angles on CT differ according to the type of valve dysfunction and a decreased opening angle may suggest an elevated PG.
Subject(s)

Full text: Available Index: WPRIM (Western Pacific) Main subject: Aortic Valve / Heart Valve Prosthesis / Tomography, X-Ray Computed / Retrospective Studies / Heart Valve Prosthesis Implantation / Heart Valve Diseases Type of study: Observational study Limits: Adult / Female / Humans / Male Language: English Journal: Korean Journal of Radiology Year: 2015 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Main subject: Aortic Valve / Heart Valve Prosthesis / Tomography, X-Ray Computed / Retrospective Studies / Heart Valve Prosthesis Implantation / Heart Valve Diseases Type of study: Observational study Limits: Adult / Female / Humans / Male Language: English Journal: Korean Journal of Radiology Year: 2015 Type: Article