Your browser doesn't support javascript.
loading
A Study of Energy Dependency in Intensity Modulated Radiation Therapy of Lung Cancer / 의학물리
Korean Journal of Medical Physics ; : 191-199, 2008.
Article in Korean | WPRIM | ID: wpr-168541
ABSTRACT
PTV considered for the energy, dose distribution exposed to lung and spinal cord, and the characteristic of DVH (Dose Volume Histogram) were compared and investigated by planning the intensity modulated radiation therapy (IMRT) using the photon energies of 6 MV and 10 MV according to tumor location like as the anterior, middle, and posterior regions of lung, and the mediastinum region in lung cancer patients. Our institution installed the linear accelerator (Varian 21 EX-s, USA) equipped with 120 multileaf collimator for lung cancer patients, which is producing the photon energies of 6 MV and 10 MV, and radiation therapy planning was performed with ECLIPSE system (Varian, SomaVision 6.5, USA), which support inverse treatment planning. The tomographic images of 3 mm slice thickness for lung cancer patients were acquired using planning CT, and acquired tomographic images were sent to the Varis system, and then treatment planning was performed in the ECLIPSE system. The radiation treatment planning of the IMRT was processed from various angles according to the regions of the tumor, and using various beam lines according to the size and location of the tumor. The investigation of the characteristic of dose distributions for the energy of 6 MV and 10 MV according to tumor locations in lung cancer patients resulted that the maximum dose of 10 MV energy was 1.2% less than that of 6 MV energy without depending on the tumor location of lung cancer, and the reduction effects of MU were occurred from 10 to 25 MU. Radiation dose exposed to the lung satisfied the less 30% of V20, however radiation dose in 6 MV energy was from 0.1% to 0.5% less than that in 10 MV energy. Radiation dose exposed to the spinal cord for 6 MV energy was from 0.6% to 2.1% less than that for 6 MV energy.
Subject(s)

Full text: Available Index: WPRIM (Western Pacific) Main subject: Particle Accelerators / Spinal Cord / Dependency, Psychological / Lung / Lung Neoplasms / Mediastinum Limits: Humans Language: Korean Journal: Korean Journal of Medical Physics Year: 2008 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Main subject: Particle Accelerators / Spinal Cord / Dependency, Psychological / Lung / Lung Neoplasms / Mediastinum Limits: Humans Language: Korean Journal: Korean Journal of Medical Physics Year: 2008 Type: Article