Your browser doesn't support javascript.
loading
Reccurent Foreign body Granuloma after Gore-tex(R) Removal in Rhinoplasty
Journal of the Korean Society of Plastic and Reconstructive Surgeons ; : 611-614, 2008.
Article in Korean | WPRIM | ID: wpr-168694
ABSTRACT

PURPOSE:

Infection, foreign body reaction and decreased volume of implant are common complications after augmentation rhinoplasty with Gore-tex(R) implant. The author experienced two cases of recurrent foreign body granuloma in the patients who underwent Gore-tex(R) removal because of infection after augmentation rhinoplasty. and treated them with complete removal of Gore-tex(R).

METHODS:

Case 1 A 49 year-old female visited our clinic for recurrent foreign body reaction on nasal dorsum and tip area. The patient underwent augmentation rhinoplasty with Gore-tex(R) 3 years ago and implant was removed due to infection 9 months ago. Excision of the granuloma was performed and a piece of foreign body suspicious to be a Gore-tex(R) implant debris was detected under the subcutaneous pocket. The implant fragments were removed and nasalis muscle rotation flap was performed to cover the lesion. The specimen was proved to be Gore-tex(R) in histological study. Case 2 A 31 year-old-male with recurrent foreign body granuloma on the nasal tip area visited our clinic. 10 years ago, the patient had augmentation rhinoplasty with silicone implant and then, he underwent revisional rhinoplasty five times including nasal implant removal, which was performed 9 months ago. The authors excised the granuloma and found a small sized foreign body suspicious to be a Gore-tex(R) implant debris under the granuloma. The foreign body was excised and identified to be Gore-tex(R) in histological study.

RESULTS:

In both cases, the lesions were healed without any complications and there were no evidences of recurrence up to 6 months of follow-up.

CONCLUSION:

The Gore-tex(R) is known to be weak against mechanical force. These properties of Gore-tex(R) make it difficult to remove the implant completely. In the patient who have infection after augmentation rhinoplasty with Gore-tex(R), the operator should take care to perform the complete removal without remaining fragment of the implant.
Subject(s)

Full text: Available Index: WPRIM (Western Pacific) Main subject: Recurrence / Rhinoplasty / Silicones / Granuloma, Foreign-Body / Follow-Up Studies / Foreign-Body Reaction / Foreign Bodies / Granuloma / Muscles Type of study: Observational study / Prognostic study Limits: Female / Humans Language: Korean Journal: Journal of the Korean Society of Plastic and Reconstructive Surgeons Year: 2008 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Main subject: Recurrence / Rhinoplasty / Silicones / Granuloma, Foreign-Body / Follow-Up Studies / Foreign-Body Reaction / Foreign Bodies / Granuloma / Muscles Type of study: Observational study / Prognostic study Limits: Female / Humans Language: Korean Journal: Journal of the Korean Society of Plastic and Reconstructive Surgeons Year: 2008 Type: Article