Fixation of Traumatic Sternal Fractures Using SternaLock Plating System
The Korean Journal of Thoracic and Cardiovascular Surgery
;
: 309-311, 2013.
Article
in English
| WPRIM
| ID: wpr-174756
ABSTRACT
A 43-year-old man experienced chest trauma due to a car accident. Compound sternal fractures with severe dislocation were seen on computed tomography of the chest. Using a SternaLock plating system with manual reduction, fixation of the sternal fracture was successfully performed. There were no complications related to the operation.
Full text:
Available
Index:
WPRIM (Western Pacific)
Main subject:
Sternum
/
Thorax
/
Joint Dislocations
Language:
English