Your browser doesn't support javascript.
loading
The evaluation of surface roughness and polishing time between polishing systems / 대한치과보존학회지
Journal of Korean Academy of Conservative Dentistry ; : 119-124, 2011.
Article in Korean | WPRIM | ID: wpr-178060
ABSTRACT

OBJECTIVES:

The purpose of this experiment was to evaluate four different polishing systems of their polishability and polishing time. MATERIALS AND

METHODS:

4 mm diameter and 2 mm thickness Teflon mold was made. Z-250 (3M ESPE) hybrid composite resin was slightly overfilled and pressed with slide glass and cured with Optilux 501 for 40 sec each side. Then the surface roughness (glass pressed control group) was measured with profilometer. One surface of the specimen was roughened by #320 grit sand paper and polished with one of the following polishing systems; Sof-Lex (3M ESPE), Jiffy (Ultradent), Enhance (Dentsply/Caulk), or Pogo (Dentsply/Caulk). The surface roughness and the total polishing time were measured. The results were analyzed with one-way ANOVA and Duncan's multiple range test.

RESULTS:

The surface roughness was lowest in Pogo, and highest in Sof-Lex. Polishing times were shortest with Pogo, and followed by the Sof-Lex, Enhance and Jiffy.

CONCLUSIONS:

One-step polishing system (Pogo) is very effective to get the smooth surface in a short time, therefore it can be recommended for final polishing system of the restoration.
Subject(s)

Full text: Available Index: WPRIM (Western Pacific) Main subject: Polytetrafluoroethylene / Chimera / Silicon Dioxide / Fungi / Glass Language: Korean Journal: Journal of Korean Academy of Conservative Dentistry Year: 2011 Type: Article

Similar

MEDLINE

...
LILACS

LIS