Effects of Intraluminal Irradiation with Holmium-166 for TIPS Stenosis: Experimental Study in a Swine Model
Korean Journal of Radiology ; : 127-135, 2007.
Article in English | WPRIM | ID: wpr-182502
ABSTRACT

OBJECTIVE:

We wanted to evaluate the effectiveness of intraluminal irradiation with Holmium-166 (166Ho) for reducing the pseudointimal hyperplasia (PIH) in the transjugular intrahepatic portosystemic shunt (TIPS) tract in a swine model. MATERIALS AND

METHODS:

TIPS was performed in 12 domestic pigs, after the creation of portal hypertension by intraportal injection of a mixture of N-butyl-2-cyanoacrylate (NBCA) and lipiodol. Five pigs first underwent intraluminal irradiation (30 Gy) in the parenchymal tract with using a 166Ho solution-filled balloon catheter, and this was followed by the placement of a nitinol stent in the TIPS tract. For the seven control pigs, the balloon was filled with saline and contrast media mixture. Two weeks later, follow-up portography and histological analysis were performed.

RESULTS:

TIPS was successfully performed in all twelve pigs with achieving artificially induced portal hypertension. Portography performed two weeks after TIPS showed the patent tracts in the TIPS tracts that were irradiated with 166Ho (5/5, 100%), whereas either completely (5/6, 83.3%) or partially (1/6, 16.7%) occluded TIPS were seen in the seven pigs of the nonirradiated control group, except in one pig that experienced periprocedural death due to bleeding. Histological analysis showed a statistically significant difference for the maximal PIH (irradiated 32.8%, nonirradiated 76.0%, p < 0.001) between the two groups.

CONCLUSION:

Intraluminal irradiation with 30 Gy of 166Ho for TIPS significantly improved the TIPS patency in a swine model of portal hypertension during a 2-week period of follow-up.
Subject(s)

Full text: Available Index: WPRIM (Western Pacific) Main subject: Radioisotopes / Swine / Stents / Constriction, Pathologic / Portasystemic Shunt, Transjugular Intrahepatic / Alloys / Holmium / Hypertension, Portal Limits: Animals Language: English Journal: Korean Journal of Radiology Year: 2007 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Main subject: Radioisotopes / Swine / Stents / Constriction, Pathologic / Portasystemic Shunt, Transjugular Intrahepatic / Alloys / Holmium / Hypertension, Portal Limits: Animals Language: English Journal: Korean Journal of Radiology Year: 2007 Type: Article