Image Settings Affecting Nuchal Translucency Measurement Using Volume NT(TM) Software
Yonsei Medical Journal ; : 1345-1351, 2015.
Article in English | WPRIM | ID: wpr-185885
ABSTRACT

PURPOSE:

To evaluate the effects of the deviation from the mid-sagittal plane, fetal image size, tissue harmonic imaging (THI), and speckle reduction filter (SRF) on the measurement of the nuchal translucency (NT) thickness using Volume NT(TM) software. MATERIALS AND

METHODS:

In 79 pregnant women, NT was measured using Volume NT(TM). Firstly, the three-dimensional volumes were categorized based on the angle of deviation in 10degrees intervals from the mid-sagittal plane. Secondly, the operator downsized the fetal image to less than 50% of the screen (Method A) and by magnifying the image (Method B). Next, the image was magnified until the fetal head and thorax occupied 75% of the screen, and the NT was measured (Method C). Lastly, NT values were acquired with THI and SRF functions on, with each function alternately on, and with both functions off.

RESULTS:

The mean differences in NT measurements were -0.09 mm (p<0.01) between two-dimensional (2D) and a deviation of 31-40degrees and -0.10 mm (p<0.01) between 2D and 41-50degrees. The intraclass correlation coefficients (ICC) for 2D-NT and NT according to image size were 0.858, 0.923, and 0.928 for methods A, B, and C, respectively. The ICC for 2D-NT and NT with respect to the THI and SRF were 0.786, 0.761, 0.740, and 0.731 with both functions on, THI only, SRF only, and with both functions off, respectively.

CONCLUSION:

NT measurements made using Volume NT(TM) are affected by angle deviation from the mid-sagittal plane and fetal image size. Additionally, the highest correlation with 2D-NT was achieved when THI and SRF functions were used.
Subject(s)

Full text: Available Index: WPRIM (Western Pacific) Main subject: Software / Image Enhancement / Sensitivity and Specificity / Imaging, Three-Dimensional / Nuchal Translucency Measurement / Embryo, Mammalian Type of study: Diagnostic study Limits: Adult / Female / Humans / Pregnancy Language: English Journal: Yonsei Medical Journal Year: 2015 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Main subject: Software / Image Enhancement / Sensitivity and Specificity / Imaging, Three-Dimensional / Nuchal Translucency Measurement / Embryo, Mammalian Type of study: Diagnostic study Limits: Adult / Female / Humans / Pregnancy Language: English Journal: Yonsei Medical Journal Year: 2015 Type: Article