ABSTRACT

PURPOSE:

We wanted to evaluate the effective methods that are appropriate for an endemic area of thyroid disease and to compare the differences of cytologic diagnostic rates with and without using a peculiar smear technique. MATERIALS AND

METHODS:

We analyzed the incidence rate of insufficient results, complications and the total procedure times of 1,126 thyroid nodules in 776 patients who underwent US-FNAB (ultrasonography-guided fine-needle aspiration biopsy) from January to December 2005. We compared the diagnostic rate between the two groups; the groups' tests were performed with a peculiar smear technique (Group A, n = 313) or with a conventional smear technique (Group B, n = 250).

RESULTS:

According to the size of the thyroid nodule, the incidence rate of an insufficient result on US-FNAB and the mean total procedure time for 1126 thyroid nodules in 776 patients were measured as 16.9% (52/308) and 208 seconds for nodules under 0.5 cm, 9.8% (30/306) and 160 seconds for nodules between 0.5 cm-1.0 cm, and 6.0% (30/504) and 134 seconds for nodules over 1.0 cm. These 776 patients showed no significant complications, except for mild pain. In Group A, the incidence rate of an insufficient result was calculated as 15.1% (14/93) for the group with nodules under 0.5 cm, 5.3% (5/95) for the group with nodules between 0.5 cm-1.0 cm, 4.8% (6/125) for the group with nodules over 1.0 cm, and 8.0% (25/313) for the total A Group. In Group B, the incidence rate of an insufficient result was measured as 33.3% (15/45) for the group with nodules under 0.5 cm, 28.1% (25/89) for the group with nodules between 0.5 cm-1.0 cm, 21.4% (24/112) for the group with nodules over 1.0 cm, and 25.7% (63/245) for the total B group. There was a statistically significant correlation between the rate of an insufficient result and the peculiar smear technique or the size of the thyroid nodule.

CONCLUSION:

We consider that US-FNAB is very simple, safe and accurate diagnostic method for thyroid nodules, and US-FNAB with a peculiar smear technique is able to increase the diagnostic rate for thyroid nodules.
Subject(s)

Full text: Available Index: WPRIM (Western Pacific) Main subject: Thyroid Diseases / Thyroid Gland / Incidence / Thyroid Nodule / Biopsy, Fine-Needle Type of study: Incidence study / Prognostic study Limits: Humans Language: Korean Journal: Journal of the Korean Radiological Society Year: 2006 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Main subject: Thyroid Diseases / Thyroid Gland / Incidence / Thyroid Nodule / Biopsy, Fine-Needle Type of study: Incidence study / Prognostic study Limits: Humans Language: Korean Journal: Journal of the Korean Radiological Society Year: 2006 Type: Article