The Incidence of Sore Throat and Hoarseness after Double-Lumen Endobronchial Tube Intubation / 대한마취과학회지
Korean Journal of Anesthesiology ; : 484-487, 1998.
Article in Korean | WPRIM | ID: wpr-193929
ABSTRACT

INTRODUCTION:

Sore throat and hoarseness often follow general anesthesia administered via a single-lumen endotracheal tube (SLT). Numerous studies have investigated the role of factors as contributing causes, but the influence of double-lumen endobronchial tube (DLT) has not been examined systemically. The goal of this study was to examine the incidence of sore throat and hoarseness after DLT insertion.

METHODS:

70 patients who were intubated with SLT or DLT were studied. Sore throat and hoarseness were evaluated after 24~48 hr from extubation of each tubes.

RESULTS:

In SLT and DLT group, the incidence of sore throat and hoarseness was 14 patients (40%) vs 16 patients (45.7%) and 8 patients (22.8%) vs 10 patients (28.5%), respectively.

CONCLUSIONS:

There are no statistical differences in incidence of sore throat and hoarseness between SLT and DLT.
Subject(s)

Full text: Available Index: WPRIM (Western Pacific) Main subject: Pharyngitis / Hoarseness / Incidence / Intubation / Anesthesia, General Type of study: Incidence study / Prognostic study Limits: Humans Language: Korean Journal: Korean Journal of Anesthesiology Year: 1998 Type: Article