Your browser doesn't support javascript.
loading
Refractive Change after Transscleral Fixation of Intraocular Lens
Journal of the Korean Ophthalmological Society ; : 548-558, 2015.
Article in Korean | WPRIM | ID: wpr-203438
ABSTRACT

PURPOSE:

To evaluate the anterior chamber depth (ACD), extent of intraocular lens (IOL) tilt, and decentration and refractive error after transscleral fixation of IOL.

METHODS:

We retrospectively reviewed the medical records of 17 cases with transscleral fixation of IOL (6 with aphakia, 5 with IOL dislocation, and 6 with lens subluxation). The acrylic IOL (MN60AC(R)) was fixated in 12 eyes and the polymethylmethacrylate IOL (CZ70BD(R)) was fixated in 5 eyes at 1.0 mm posterior from the limbus. We analyzed the ACD, extent of IOL tilt and decentration, manifest refraction, refractive error, higher order aberration, and corneal endothelium at 2 weeks, 1 month and 2 months postoperatively.

RESULTS:

The mean ACD was 3.36 +/- 0.11 mm, 3.30 +/- 0.12 mm, and 3.27 +/- 0.13 mm, the mean extent of IOL tilt was 4.61 +/- 0.12degrees, 4.65 +/- 0.14degrees, and 4.60 +/- 0.12degrees and the mean extent of IOL decentration was 0.43 +/- 0.01 mm, 0.45 +/- 0.01 mm, and 0.45 +/- 0.01 mm at 2 weeks, 1 month and 2 months postoperatively, respectively in eyes with transscleral fixation of IOL. The ACD was shallower and the extent of IOL tilt and decentration was greater than with IOL in-the-bag insertion patients. The mean refractive errors were -0.55 +/- 0.27 D, -0.63 +/- 0.24 D, and -0.69 +/- 0.19 D at the same period, respectively.

CONCLUSIONS:

Although postoperative refractive error is influenced by surgeon factors such as incision size, distance of fixation suture from limbus, and tightness of suture material, according to our results, an IOL 0.75 D more hyperopic than predicted should be selected in transscleral fixation of IOL at 1.0 mm posterior from the limbus. Additionally, each surgeon should assess their specific results and modify the lens calculations accordingly.
Subject(s)

Full text: Available Index: WPRIM (Western Pacific) Main subject: Aphakia / Refractive Errors / Sutures / Endothelium, Corneal / Medical Records / Retrospective Studies / Polymethyl Methacrylate / Joint Dislocations / Lenses, Intraocular / Anterior Chamber Type of study: Observational study / Prognostic study Limits: Humans Language: Korean Journal: Journal of the Korean Ophthalmological Society Year: 2015 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Main subject: Aphakia / Refractive Errors / Sutures / Endothelium, Corneal / Medical Records / Retrospective Studies / Polymethyl Methacrylate / Joint Dislocations / Lenses, Intraocular / Anterior Chamber Type of study: Observational study / Prognostic study Limits: Humans Language: Korean Journal: Journal of the Korean Ophthalmological Society Year: 2015 Type: Article