Your browser doesn't support javascript.
loading
Effect of light source and shade on depth of cure of composites / 대한치과보존학회지
Journal of Korean Academy of Conservative Dentistry ; : 561-568, 2002.
Article in Korean | WPRIM | ID: wpr-203714
ABSTRACT
Purpose of this research is estimating polymerization depth of different source of light. XL 3000 for halogen light, Apollo 95E for plasma arc light and Easy cure for LED light source were used in this study. Different shade (B1 & A3) resin composites (Esthet-X, Dentsply, U.S.A.) were used to measure depth of cure. 1, 2, and 3 mm thick samples were light cured for three seconds, six seconds or 10 seconds with Apollo 95E and they were light cured with XL-3000 and Easy cure for 10 seconds, 20 seconds, or 40 seconds. Vicker's hardness test carried out after store samples for 24 hours in distilled water. Results were as following. 1. Curing time increases from all source of lights, curing depth increased(p0.05). 4. Groups that do polymerization using Plasma arc and LED source of light did not show Vicker's hardness difference according to color at surface and 1mm depth(p>0.05), but showed difference according to color at 2mm and 3mm depth(p<0.05). The results showed that Apollo 95E need more polymerization times than manufacturer's recommendation (3 seconds), and Easy cure need polymerization time of XL-3000 at least.
Subject(s)

Full text: Available Index: WPRIM (Western Pacific) Main subject: Plasma / Polymers / Polymethyl Methacrylate / Polymerization / Hardness / Hardness Tests / Light Language: Korean Journal: Journal of Korean Academy of Conservative Dentistry Year: 2002 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Main subject: Plasma / Polymers / Polymethyl Methacrylate / Polymerization / Hardness / Hardness Tests / Light Language: Korean Journal: Journal of Korean Academy of Conservative Dentistry Year: 2002 Type: Article