10-Prism-Diopter Fixation Test for Amblyopia
Journal of the Korean Ophthalmological Society
;
: 269-274, 2009.
Article
in Korean
| WPRIM
| ID: wpr-211849
ABSTRACT
PURPOSE:
To evaluate the clinical usefulness of the 10-prism-diopter (PD) fixation test in the diagnosis of amblyopia.METHODS:
The study comprised 132 children (42 normal, 90 amblyopes) who underwent the 10-PD fixation test and stereoacuity test. The sensitivity, specificity, false-positive and false-negative rates of the 10-PD fixation test were analyzed according to the clinical diagnosis.RESULTS:
The 10-PD fixation test sensitivity was 86%, the specificity was 61%, the false-positive rate was 17% and the false-negative rate was 24%. Data showed agreement between the 10-PD fixation test and the stereoacuity test (gamma=0.737, p=0.000). The results in the 10-PD base-down test and base-out test also showed agreement (gamma=0.779, p=0.000).CONCLUSIONS:
The 10-PD fixation test is a simple and useful method in detecting amblyopia.