ABSTRACT
An acute thromboembolism of the peripheral artery is a common complication in patient with inappropriately treated atrial fibrillation. A case of successful recanalization of a thromboembolic occlusion of the left common femoral artery, using the PercuSurge GuardWire(TM) System, with a 7 Fr. guiding catheter, was experienced in a patient with atrial fibrillation.
Subject(s)

Full text: Available Index: WPRIM (Western Pacific) Main subject: Arteries / Atrial Fibrillation / Thromboembolism / Embolectomy / Femoral Artery / Catheters Limits: Humans Language: Korean Journal: Korean Circulation Journal Year: 2004 Type: Article