Your browser doesn't support javascript.
loading
Color difference of the dental composites measured by different color measuring instruments / 대한치과보존학회지
Journal of Korean Academy of Conservative Dentistry ; : 199-207, 2009.
Article in Korean | WPRIM | ID: wpr-21551
ABSTRACT
The objective of this study was to evaluate the effect of color measuring instrument by measuring the color of dental composite resins. Nine shade light cured composite resin disks were prepared (diameter 15 mm, thickness 4 mm). CIE L*a*b* color scale of each disk was measured with 3 different types of spectrophotometer [MiniScan XE plus (Model 4000S, Hunter Lab, USA), CM-3500d (Minolta, Japan) and Specbos 2100 Miniature VIS Reflection spectrometer (Serial No 319416, JETI Technishe VIS Instrumentic GmbH, Germany)]. Miniscan XE Plus and CM-3500d using identical measuring geometry with different size of viewing aperture. But Specbos 2100 using different measuring geometry. Within the limitation of this study, there were color difference (DeltaE*) from 2.4 to 7.8 between Miniscan XE Plus and CM-3500d, but L*, a*, b* values showed the high correlation. However, there were great color difference (DeltaE*) in the extent of about 20 between instruments with the different measuring geometry. Therefore, color scale measured by color measuring instrument should be used as a relative value rather than an absolute value in the field of dentistry.
Subject(s)

Full text: Available Index: WPRIM (Western Pacific) Main subject: Pyridines / Thiazoles / Dentistry / Light Language: Korean Journal: Journal of Korean Academy of Conservative Dentistry Year: 2009 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Main subject: Pyridines / Thiazoles / Dentistry / Light Language: Korean Journal: Journal of Korean Academy of Conservative Dentistry Year: 2009 Type: Article