Dosimetry and MIRD for Re-188 Liquid Balloons / 대한핵의학회잡지
Korean Journal of Nuclear Medicine ; : 222-227, 1999.
Article in Korean | WPRIM | ID: wpr-216279
ABSTRACT
Re-188 is suitable for endovascular liquid-balloon brachytherapy for the prevention of restenosis after angioplasty. Re-188 was concentrated to 3700 MBq/ml and labeled with DTPA. According to dosimetric calculation, it took 420 seconds using Re-188 solution with concentration of 3700 MBq/ml to irradiate 17.6 Gy to the target at 1 mm from the balloon surface. Software was made to estimate the irradiation time. MIRD calculation with dynamic bladder model yielded the whole body dose of Re-188-DTPA as 0.005mGy/MBq in case of balloon rupture and release of the whole amount into the blood.
Subject(s)

Full text: Available Index: WPRIM (Western Pacific) Main subject: Rupture / Urinary Bladder / Brachytherapy / Angioplasty / Pentetic Acid Language: Korean Journal: Korean Journal of Nuclear Medicine Year: 1999 Type: Article