Your browser doesn't support javascript.
loading
Diagnostic Value of MR Imaging in Differentiation of Meniscal Tear Patterns
Journal of the Korean Radiological Society ; : 159-164, 1999.
Article in Korean | WPRIM | ID: wpr-220228
ABSTRACT

PURPOSE:

To evaluate the diagnostic accuracy of magnetic resonance (MR) imaging in the differentiation ofmeniscal tear patterns of the knee. MATERIALS AND

METHODS:

MR images of 93 patients with meniscal tear wereincluded in this study. On the basis of arthroscopic findings, the configuration of meniscal tears was classifiedas horizontal (n=44), longitudinal (n=34), transverse (n=11), or oblique (n=5). Oblique sagittal and coronal MRimages were obtained and com-pared with the arthroscopic findings.

RESULTS:

Among 94 cases ofarthroscopically-proven meniscal tears, 35 of 44 horizontal and 27 of 34 longitudi-nal configurations werecorrectly interpreted on MR images. Sensitivity and specificity for horizontal configu-ration were 80 % and 80 %,respectively, while the corresponding values for longitudinal configuration were 79 % and 95 %. On MR images, tworadial configurations were correctly interpreted from 11 confirmed tears and only one oblique configuration fromfive confirmed tears.

CONCLUSION:

MR imaging was useful for the differentiation of horizontal and longitudinaltears, but inaccurate in cases involving radial or oblique tears.
Subject(s)

Full text: Available Index: WPRIM (Western Pacific) Main subject: Magnetic Resonance Imaging / Sensitivity and Specificity / Knee Type of study: Diagnostic study Limits: Humans Language: Korean Journal: Journal of the Korean Radiological Society Year: 1999 Type: Article