Your browser doesn't support javascript.
loading
The Application of a Bi-ventricular Assist Device for a Low Weight (2.4 kg) Neonate with Coarctation of the Aorta and Critical Aortic Stenosis / 대한흉부외과학회지
The Korean Journal of Thoracic and Cardiovascular Surgery ; : 304-307, 2010.
Article in Korean | WPRIM | ID: wpr-223914
ABSTRACT
A 5-day-old neonate (body weight=2.4 kg) with coarctation of the aorta and critical aortic stenosis underwent an interventional balloon valvuloplasty for aortic stenosis. During the intervention, cardiac arrest occurred due to injury of the right carotid artery by the guide wire. An extracorporeal membrane oxygenator (ECMO) was applied. After 1 day's support, total surgical correction was achieved; however, in the immediate postoperative period, cardiac function was severely depressed. We applied a bi-ventricular assist device (bi-VAD) instead of an ECMO and we were able to wean the patient off the bi-VAD device after 3 days' support. The patient was discharged without severe complications.
Subject(s)

Full text: Available Index: WPRIM (Western Pacific) Main subject: Aortic Coarctation / Aortic Valve Stenosis / Oxygenators, Membrane / Postoperative Period / Extracorporeal Membrane Oxygenation / Carotid Arteries / Heart-Assist Devices / Extracorporeal Circulation / Balloon Valvuloplasty / Heart Arrest Limits: Humans / Infant, Newborn Language: Korean Journal: The Korean Journal of Thoracic and Cardiovascular Surgery Year: 2010 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Main subject: Aortic Coarctation / Aortic Valve Stenosis / Oxygenators, Membrane / Postoperative Period / Extracorporeal Membrane Oxygenation / Carotid Arteries / Heart-Assist Devices / Extracorporeal Circulation / Balloon Valvuloplasty / Heart Arrest Limits: Humans / Infant, Newborn Language: Korean Journal: The Korean Journal of Thoracic and Cardiovascular Surgery Year: 2010 Type: Article