Your browser doesn't support javascript.
loading
Difficult tracheostomy tube placement in an obese patient with a short neck: A case report / 대한마취과학회지
Korean Journal of Anesthesiology ; : 434-436, 2011.
Article in English | WPRIM | ID: wpr-226274
ABSTRACT
We report a difficult case of tracheostomy in a 34-year-old obese woman with a short neck. The tracheostomy tube placement repeatedly failed because of anatomical changes due to obesity and a short neck, tracheal mucosal swelling due to prolonged intubation, and unexpected false passage; however, it was successfully performed using an endotracheal tube exchanger as a guidewire.
Subject(s)

Full text: Available Index: WPRIM (Western Pacific) Main subject: Tracheostomy / Intubation / Neck / Obesity Limits: Adult / Female / Humans Language: English Journal: Korean Journal of Anesthesiology Year: 2011 Type: Article