Your browser doesn't support javascript.
loading
Short-term results of modular extensively porous-coated revision stem in revision total hip arthroplasty / 中国医学科学院学报
Acta Academiae Medicinae Sinicae ; (6): 182-187, 2004.
Article in Chinese | WPRIM | ID: wpr-231963
ABSTRACT
<p><b>OBJECTIVE</b>To evaluate the short-term clinical and radiographic results of modular fully porous-coated stem in revision operation of total hip arthroplasty.</p><p><b>METHODS</b>From May 2001 to November 2002, ten cases with twelve hips received revision total hip arthroplasty using modular Profemur R with fully porous-coated stem. There were three males and seven females and the average age was 54.2 years (35 to approximately 71 years). The reasons for revision operation included aseptic loosing in eleven hips and septic loosing in one hip. All the patients were evaluated radiographically and clinically. Radiographic evaluation included the classification of bone loss, leg discrepancy, offset and antiversion before and after revision and bone in-growth postoperatively. Clinical evaluation were based on Harris score system.</p><p><b>RESULTS</b>The average follow-up period is 13.5 months (range 6 to approximately 24 months). Leg discrepancy from more than 2 cm in six cases were restored to less than 1 cm postoperatively. Femoral offset, antiversion angle and neck-shaft angle were also restored to normal limitation. All the patients were allowed to full weight-bearing 3 to approximately 5 months later and pain relief occurred in all involved hips. At the last follow-up, bone in-growth occurred in eleven hips and solid fibrous fixation only in one case. Harris score was improved from a mean of 25 to 72. Complications mainly consisted of femoral shaft fracture in three cases but no infection or dislocation was found postoperatively.</p><p><b>CONCLUSIONS</b>Satisfactory results of short-term radiographic and clinical follow-up can be achieved using modular fully porous-coated stem for revision total hip arthroplasty.</p>
Subject(s)
Full text: Available Index: WPRIM (Western Pacific) Main subject: Reoperation / Bone Cements / Prosthesis Failure / Diagnostic Imaging / Radiography / Follow-Up Studies / Cementation / Arthroplasty, Replacement, Hip / Coated Materials, Biocompatible / Therapeutic Uses Type of study: Diagnostic study / Observational study / Prognostic study Limits: Adult / Aged / Female / Humans / Male Language: Chinese Journal: Acta Academiae Medicinae Sinicae Year: 2004 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Main subject: Reoperation / Bone Cements / Prosthesis Failure / Diagnostic Imaging / Radiography / Follow-Up Studies / Cementation / Arthroplasty, Replacement, Hip / Coated Materials, Biocompatible / Therapeutic Uses Type of study: Diagnostic study / Observational study / Prognostic study Limits: Adult / Aged / Female / Humans / Male Language: Chinese Journal: Acta Academiae Medicinae Sinicae Year: 2004 Type: Article