500 Hz masking level difference test for Chinese: a pilot study / 中华耳鼻咽喉头颈外科杂志
Article in Zh | WPRIM | ID: wpr-233806
Responsible library: WPRO
ABSTRACT
<p><b>OBJECTIVE</b>A pilot study found the masking level difference (MLD) normal value of Chinese aged from 10 to 40, served to clinical practice.</p><p><b>METHOD</b>Seventy-three normal persons with hearing threshold < 20 dB and no disorder of otology were divided into three groups: classified 10-20 age as A group, 21-30 age as B group, 31-40 age as C group. MLD of age, gender and race were determined by the audiometer with dual channel by playing audio test disc. Same tests were compared with English language.</p><p><b>RESULTS</b>The mean value of MLD in Chinese was (11.1 ± 3.4) dB and the 95% normal reference values were between 4.4 to 17.8 dB . There was no difference in term of gender. The value of MLD increased with age. In the term of language, foreign showed high value of MLD than that of Chinese.</p><p><b>CONCLUSIONS</b>The measuring of MLD depends on age and language but not depends on gender. The normal threshold of MLD depends on age and language should be measured when normal values were applied to assess MLD in clinical practice.</p>
Subject(s)
Full text: 1 Index: WPRIM Main subject: Otolaryngology / Perceptual Masking / Reference Values / Audiometry / Auditory Threshold / China / Pilot Projects / Asian People / Hearing Tests / Language Limits: Humans Country/Region as subject: Asia Language: Zh Journal: Chinese Journal of Otorhinolaryngology Head and Neck Surgery Year: 2014 Type: Article
Full text: 1 Index: WPRIM Main subject: Otolaryngology / Perceptual Masking / Reference Values / Audiometry / Auditory Threshold / China / Pilot Projects / Asian People / Hearing Tests / Language Limits: Humans Country/Region as subject: Asia Language: Zh Journal: Chinese Journal of Otorhinolaryngology Head and Neck Surgery Year: 2014 Type: Article