Your browser doesn't support javascript.
loading
Comparative study of optic disc measurement by Copernicus optical coherence tomography and Heidelberg retinal tomography / 中华医学杂志(英文版)
Chinese Medical Journal ; (24): 2858-2861, 2012.
Article in English | WPRIM | ID: wpr-244336
ABSTRACT
<p><b>BACKGROUND</b>Copernicus optical coherence tomography (SOCT) is a new, ultra high-speed and high-resolution instrument available for clinical evaluation of optic nerve. The purpose of the study was to compare the agreements between SOCT and Heidelberg retinal tomography (HRT).</p><p><b>METHODS</b>A total of 44 healthy normal volunteers were recruited in this study. One eye in each subject was selected randomly. Agreement between SOCT and HRT-3 in measuring optic disc area was assessed using Bland-Altman plots. Relationships between measurements of optic nerve head parameter obtained by SOCT and HRT-3 were assessed by Pearson correlation.</p><p><b>RESULTS</b>There was no significant difference in the average cup area (0.306 vs. 0.355 mm, P = 0.766), cup volume (0.158 vs. 0.130 mm, P = 0.106) and cup/disc ration (0.394 vs. 0.349 mm, P = 0.576) measured by the two instruments. However, other optic disc parameters from SOCT were significantly lower compared with HRT-3. The Bland-Altman plot revealed good agreement of cup area and cup volume measured by SOCT and HRT-3. Bad agreement of disc area, rim area, rim volume and cup/disc ratio were found between SOCT and HRT-3. The highest correlations between the two instruments were observed for cup area (r(2) = 0.783, P = 0.000) and cup/disc ratio (r(2) = 0.669, P = 0.000), whereas the lowest correlation was observed for disc area (r(2) = 0.100, P = 0.037), rim area (r(2) = 0.275, P = 0.000), cup volume (r(2) = 0.005, P = 0.391) and rim volume (r(2) = 0.021, P = 0.346).</p><p><b>CONCLUSIONS</b>There were poor agreements between SOCT and HRT-3 for measurement of optic nerve parameters except cup area and cup volume. Measurement results of the two instruments are not interchangeable.</p>
Subject(s)
Full text: Available Index: WPRIM (Western Pacific) Main subject: Optic Disk / Pathology / Retina / Tomography / Tomography, Optical Coherence / Methods Limits: Adolescent / Adult / Female / Humans / Male Language: English Journal: Chinese Medical Journal Year: 2012 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Main subject: Optic Disk / Pathology / Retina / Tomography / Tomography, Optical Coherence / Methods Limits: Adolescent / Adult / Female / Humans / Male Language: English Journal: Chinese Medical Journal Year: 2012 Type: Article