ABSTRACT
The robust extracting of evoked potential (EP) has become a vexed question in the process of electroencephalogram owing to the faint signal-to-noise ratio of EP. This paper presents the single trial of EP in time, transform and space field. Several methods such as adaptive filter, wavelet transform, principal component analysis (PCA) and independent component analysis (ICA) have been applied to the process of EP.
Subject(s)
Full text: Available Index: WPRIM (Western Pacific) Main subject: Physiology / Algorithms / Signal Processing, Computer-Assisted / Brain / Principal Component Analysis / Electroencephalography / Evoked Potentials / Methods Limits: Humans Language: Chinese Journal: Journal of Biomedical Engineering Year: 2009 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Main subject: Physiology / Algorithms / Signal Processing, Computer-Assisted / Brain / Principal Component Analysis / Electroencephalography / Evoked Potentials / Methods Limits: Humans Language: Chinese Journal: Journal of Biomedical Engineering Year: 2009 Type: Article