Your browser doesn't support javascript.
loading
Laser-induced interstitial thermotherapy via a single-needle delivery system: Optimal conditions of ablation, pathological and ultrasonic changes / 华中科技大学学报(医学)(英德文版)
Journal of Huazhong University of Science and Technology (Medical Sciences) ; (6): 579-584, 2015.
Article in English | WPRIM | ID: wpr-250374
ABSTRACT
This study aimed to examine the optimal conditions of laser-induced interstitial thermotherapy (LITT) via a single-needle delivery system, and the ablation-related pathological and ultrasonic changes. Ultrasound (US)-guided LITT (EchoLaser system) was performed at the output power of 2-4 Wattage (W) for 1-10 min in ex vivo bovine liver. Based on the results of the ex vivo study, the output power of 3 and 4 W with different durations was applied to in vivo rabbit livers (n=24), and VX2 tumors implanted in the hind limbs of rabbits (n=24). The ablation area was histologically determined by hematoxylin-eosin (HE) staining. Traditional US and contrast enhanced ultrasound (CEUS) were used to evaluate the treatment outcomes. The results showed (1) In the bovine liver, ablation disruption was grossly seen, including a strip-like ablation crater, a carbonization zone anteriorly along the fiber tip, and a surrounding gray-white coagulation zone. The coagulation area, 1.2 cm in length and 1.0 cm in width, was formed in the bovine liver subjected to the ablation at 3 W for 5 min and 4 W for 4 min, and it extended slightly with the ablation time. (2) In the rabbit liver, after LITT at 3 W for 3 min and more, the coagulation area with length greater than or equal to 1.2 cm, and width greater than or equal to 1.0 cm, was found. Similar coagulation area was seen in the implanted VX2 carcinoma at 3 W for 5 min. (3) Gross examination of the liver and carcinoma showed three distinct regions ablation crater/carbonization, coagulation and congestion distributed from the center outwards. (4) Microscopy revealed four zones after LITT, including ablation crater/carbonization, coagulation, edema and congestion from the center outwards. A large area with coagulative necrosis was observed around a vessel in the peripheral area with edema and hyperemia. (5) The size of coagulation was consistent well to the CEUS findings. It was concluded that EchoLaser system at low power can produce a coagulation area larger than 1.0 cm×1.0 cm during a short time period. The real-time US imaging can be used to effectively guide and assess the treatment.
Subject(s)
Full text: Available Index: WPRIM (Western Pacific) Main subject: Pathology / Therapeutics / Ultrasonic Therapy / Bone Neoplasms / Diagnostic Imaging / Ultrasonography / Treatment Outcome / Laser Therapy / Hindlimb / Liver Diseases Type of study: Diagnostic study Limits: Animals Language: English Journal: Journal of Huazhong University of Science and Technology (Medical Sciences) Year: 2015 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Main subject: Pathology / Therapeutics / Ultrasonic Therapy / Bone Neoplasms / Diagnostic Imaging / Ultrasonography / Treatment Outcome / Laser Therapy / Hindlimb / Liver Diseases Type of study: Diagnostic study Limits: Animals Language: English Journal: Journal of Huazhong University of Science and Technology (Medical Sciences) Year: 2015 Type: Article