The application of rhinoscope in microsurgical treatment of intracranial aneurysms intraoperative clinical research / 中国医疗器械杂志
Chinese Journal of Medical Instrumentation
;
(6): 312-314, 2014.
Article
in Chinese
| WPRIM
| ID: wpr-259861
ABSTRACT
This paper analysed the rhinoscope's clinical value in microsurgical treatment of intracranial aneurysms. Application of the rhinoscope in 87 patients, only 2 patients had ruptured during operation. However, 11 cases had ruptured in 94 cases without using rhinoscope, P < 0.05, they had a significant difference. By DSA follow-up review, 82 cases of used rhinoscope only 2 cases had remained the aneurysm neck, but 9 cases had the aneurysm neck in 77 cases which had not used the rhinoscope in the microsurgical treatment, P < 0.05, they also had significant difference. The application of rhinoscope in microsurgical treatment of intracranial aneurysms intraoperative, can reduce the risk of the intraoperative aneurysm rupture. It can achieve better clinical effect.
Full text:
Available
Index:
WPRIM (Western Pacific)
Main subject:
General Surgery
/
Intracranial Aneurysm
/
Nose
/
Treatment Outcome
/
Endoscopy
/
Microsurgery
Limits:
Adult
/
Aged
/
Female
/
Humans
/
Male
Language:
Chinese
Journal:
Chinese Journal of Medical Instrumentation
Year:
2014
Type:
Article
Similar
MEDLINE
...
LILACS
LIS