A three-dimensional finite element analysis of stress distribution in mandibular FPDs with different length pontics / 中华口腔医学杂志
Chinese Journal of Stomatology
;
(12): 133-135, 2004.
Article
in Chinese
| WPRIM
| ID: wpr-263438
ABSTRACT
<p><b>OBJECTIVE</b>To investigate the stress distribution in the mandibular fixed partial denture (FPD) by changing the length of pontics.</p><p><b>METHODS</b>Based on a 3-DFE model of the mandibular FPD, we analyzed the stress distribution in the mandibular FPDs by loading the same level force at pontics with different lengths that were 2 to 4 times of normal length.</p><p><b>RESULTS</b>The distribution trends of the stresses in the mandibular FPDs with differently elongated pontics were similar, but the highest von Mises stress in the bridge was enlarged.</p><p><b>CONCLUSION</b>Damages may develop in the mandibular FDP, when the length of the pontic is longer than 3 times of normal length.</p>
Full text:
Available
Index:
WPRIM (Western Pacific)
Main subject:
Finite Element Analysis
/
Dental Stress Analysis
/
Denture, Partial, Fixed
/
Mandible
Limits:
Humans
Language:
Chinese
Journal:
Chinese Journal of Stomatology
Year:
2004
Type:
Article