Your browser doesn't support javascript.
loading
Comparison of two contrast agents for diagnosis of patent foramen ovale by contrast transcranial Doppler / 南方医科大学学报
Journal of Southern Medical University ; (12): 1075-1079, 2016.
Article in Chinese | WPRIM | ID: wpr-286845
ABSTRACT
<p><b>OBJECTIVE</b>To compare agitated saline solution (AS) and the mixture of AS with blood (ASb) as the contrast agents in contrast transcranial Doppler (c-TCD) in the diagnosis of patent foramen ovale (PFO).</p><p><b>METHODS</b>We recruited 248 consecutive patients for c-TCD examination between November 2015 and January 2016, and the sequence of the use of AS (9 mL saline solution mixed with 1 mL air) and ASb (9 mL saline solution and a drop of the patient's blood mixed with 1 mL air) was determined by coin-tossing method. Before the examination, the contrast agent was injected with or without Valsalva maneuvers (VM), and the number of microbubbles within 25 s after the contrast agent injection and the time of first appearance of microbubbles were recorded by observing the TCD spectrum. Each injection was repeated twice and the interval between tests was at least 5 min. We classified PFO according to the number of microbubbles into negative (no microbubble), grade I (1-10 microbubbles), grade II (>10 microbubbles but no curtain), and grade III (with curtain).</p><p><b>RESULTS</b>s The positivity rates in diagnosis with AS without VM, AS with VM, ASb without VM, and ASb with VM tests were 10.9%, 23.8%, 12.1% and 25.8%, respectively. AS with VM test had a higher positive rate than AS without VM test (23.8% vs 10.9%, P=0.001), and ASb with VM test had a higher positive rate than ASb without VM test (25.8% vs 12.1%, P=0.001). The positive rates were similar between ASb without VM and AS without VM test (12.1% vs 10.9%, P=0.250) and between ASb with VM test and AS with VM test (25.8% vs 23.8%, P=0.125).</p><p><b>CONCLUSION</b>VM can improve the positive rate of PFO diagnosis in c-TCD examination, and the positive rates are comparable between examinations using the contrast agents AS and ASb.</p>
Subject(s)
Full text: Available Index: WPRIM (Western Pacific) Main subject: Diagnostic Imaging / Sodium Chloride / Chemistry / Valsalva Maneuver / Sensitivity and Specificity / Ultrasonography, Doppler, Transcranial / Contrast Media / Microbubbles / Foramen Ovale, Patent Type of study: Diagnostic study Language: Chinese Journal: Journal of Southern Medical University Year: 2016 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Main subject: Diagnostic Imaging / Sodium Chloride / Chemistry / Valsalva Maneuver / Sensitivity and Specificity / Ultrasonography, Doppler, Transcranial / Contrast Media / Microbubbles / Foramen Ovale, Patent Type of study: Diagnostic study Language: Chinese Journal: Journal of Southern Medical University Year: 2016 Type: Article