ABSTRACT
<p><b>OBJECTIVE</b>To compare the effectiveness of high-frequency jet ventilation via Wei jet nasal airway and controlled ventilation with improved laryngeal mask airway during bronchial thermoplasty.</p><p><b>METHODS</b>Twenty-eight patients undergoing bronchial thermoplasty were equally divided into two groups group A (high-frequency jet ventilation through Wei jet nasal airway) and group B (controlled ventilation with improved laryngeal mask airway). Pulse oxygenation,heart rate,and mean arterial blood pressure were recorded after entering the operating room (T0), 1 minute after administration/induction (T1), bronchoscope inserting (T2), 15 minutes (T3)/30 minutes (T4)/45 minutes (T5) after ventilation,at the end of the operation (T6), and at the recovery of patients' consciousness (T7). The pH,arterial oxygen partial pressure,and arterial carbon dioxide partial pressure were recorded at T0, T4, and T6. The endoscope indwelling duration,operative time,patients' awakening time,adverse events during anesthesia,satisfactions of patients and operators, anesthesic effectiveness were also recorded.</p><p><b>RESULTS</b>The arterial carbon dioxide partial pressur in group A at T4 and T6 were significantly higher than in group B (P<0.05). The pH in group A at T4 and T6 was significantly lower than in group B (P<0.05). The endoscope indwelling duration and the operative time in group B were significantly shorter than in group A (P<0.05) while the recovery of consciousness in group B was significantly longer than in group A (P<0.05). The satisfaction for operators and the efficacy of anesthesia in group B were better than in group A (P<0.05). The number of adverse events in group B was significantly smaller than in group A (P<0.05).</p><p><b>CONCLUSION</b>The improved laryngeal mask airway with controlled ventilation is more suitable for bronchial thermoplasty.</p>
Subject(s)
Full text: Available Index: WPRIM (Western Pacific) Main subject: Blood Gas Analysis / Bronchoscopy / High-Frequency Jet Ventilation / Laryngeal Masks / Catheter Ablation / Heart Rate Limits: Humans Language: Chinese Journal: Acta Academiae Medicinae Sinicae Year: 2016 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Main subject: Blood Gas Analysis / Bronchoscopy / High-Frequency Jet Ventilation / Laryngeal Masks / Catheter Ablation / Heart Rate Limits: Humans Language: Chinese Journal: Acta Academiae Medicinae Sinicae Year: 2016 Type: Article