Biomechanical performance of different wires and cable fixation devices in posterior instrumentation for atlantoaxial instability / 南方医科大学学报
Journal of Southern Medical University ; (12): 1127-1131, 2010.
Article in Chinese | WPRIM | ID: wpr-289976
ABSTRACT
<p><b>OBJECTIVE</b>To compare the biomechanical performances of different wires and cable fixation devices in posterior instrumentation for atlantoaxial instability, and test the effect of different fixation strengths and fixation approaches on the surgical outcomes.</p><p><b>METHODS</b>Six specimens of the atlantoaxial complex (C0-C3) were used to establish models of the normal complex, unstable complex (type II odontoid fracture) and fixed complex. On the wd-5 mechanical testing machine, the parameters including the strength and rigidity of anti-rotation, change and strength of stress, and stability were measured for the normal complex, atlantoaxial instability complex, the new type titanium cable fixation system, Atlas titanium cable, Songer titanium cable, and stainless wire.</p><p><b>RESULTS</b>The strength and rigidity of anti-rotation, change and strength of stress, stability of flexion, extension and lateral bending of the unstable atlantoaxial complex fixed by the new double locking titanium cable fixation system were superior to those of the Songer or Atlas titanium cable (P<0.05) and medical stainless wire (P<0.05). Simultaneous cable fastening on both sides resulted in better fixation effect than successive cable fastening (P<0.05). Better fixation effect was achieved by fastening the specimen following a rest (P<0.05).</p><p><b>CONCLUSIONS</b>The fixation effects can be enhanced by increased fastening strengths. The new type double locking titanium cable fixation system has better biomechanical performance than the conventional Songer and Atlas titanium cables. Fastening the unstable specimens after a rest following simultaneous fastening of the specimen on both sides produces better fixation effect.</p>
Subject(s)
Full text: Available Index: WPRIM (Western Pacific) Main subject: Orthopedic Fixation Devices / Atlanto-Axial Joint / General Surgery / Biomechanical Phenomena / Bone Wires / Cadaver / Internal Fixators / Joint Instability Limits: Humans Language: Chinese Journal: Journal of Southern Medical University Year: 2010 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Main subject: Orthopedic Fixation Devices / Atlanto-Axial Joint / General Surgery / Biomechanical Phenomena / Bone Wires / Cadaver / Internal Fixators / Joint Instability Limits: Humans Language: Chinese Journal: Journal of Southern Medical University Year: 2010 Type: Article