Your browser doesn't support javascript.
loading
Cannulated screw combined with buttress plate for the treatment of transarticular shear fractures of the distal humerus / 中国骨伤
China Journal of Orthopaedics and Traumatology ; (12): 161-164, 2014.
Article in Chinese | WPRIM | ID: wpr-301868
ABSTRACT
<p><b>OBJECTIVE</b>To investigate the clinical outcomes of cannulated screw combined with buttress plate in treating transarticular shear fractures of the distal humerus.</p><p><b>METHODS</b>From July 2008 to December 2011, 17 patients with shear fractures of the distal humerus were treated with cannulated screw combined with buttress plate. Among them, included 10 males and 7 females aged from 20 to 59 years old (mean 36.5). All the fractures were classified into type I (8 cases), type II (1 case), type III (3 cases) and type IV (5 cases) according to Bryan-Morrey and McKee classification. According to AO/ASIF classification, 10 cases were type 13B3.1, 7 cases were type 13B3.3; according to Dubberley classification, 5 cases with type 1A, 2 cases with type 1B, 2 cases with type 2A, 2 cases with type 2B, 4 cases with type 3A, 2 cases with type 3B. There were 12 cases with fresh injuries, 4 cases with old injuries. All fractures were closed injuries. Complications and range of motion of elbow were observed, and clinical efficacy were evaluated by Broberg-Morrey standard.</p><p><b>RESULTS</b>All patients were followed up with a mean time of 21.3 months (ranged, 18 to 24). All fractures obtained bone healing from 10 to 15 weeks with a mean of 12.5 weeks. No malunion or delayed healing occurred. Two cases occurred ossification in lateral collateral ligament attachment. 2 cases occurred heterotopic ossification in the capitellum in front of capsule joint. The range of elbow extension was (16 +/- 7) degrees, flexion was (115 +/- 9) degrees, the average are of pronation and supination was (65 +/- 5) degrees and (60 +/- 5) degrees respectively. According to Broberg-Morrey standard, there were excellent in 7 cases, good in 8 cases, fair in 2 cases, and average score was 92.44 +/- 4.64.</p><p><b>CONCLUSION</b>For transarticular shear fractures of the distal humerus, classification should be performed according to preoperative X-ray and CT, cannulated screw and buttress plate combined and early function rehabilitation could recover elbow function.</p>
Subject(s)
Full text: Available Index: WPRIM (Western Pacific) Main subject: General Surgery / Bone Plates / Bone Screws / Range of Motion, Articular / Fracture Fixation, Internal / Humeral Fractures / Methods Limits: Adult / Female / Humans / Male Language: Chinese Journal: China Journal of Orthopaedics and Traumatology Year: 2014 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Main subject: General Surgery / Bone Plates / Bone Screws / Range of Motion, Articular / Fracture Fixation, Internal / Humeral Fractures / Methods Limits: Adult / Female / Humans / Male Language: Chinese Journal: China Journal of Orthopaedics and Traumatology Year: 2014 Type: Article