Efficacy of personalized endovascular repair using two stent-grafts for patients with Stanford B aortic dissection / 中华心血管病杂志
Chinese Journal of Cardiology
;
(12): 39-43, 2015.
Article
in Chinese
| WPRIM
| ID: wpr-303770
ABSTRACT
<p><b>OBJECTIVE</b>To observe the feasibility and clinical efficacy of thoracic endovascular aortic repair (TEVAR) for patients with Stanford B aortic dissection using personalized two stent-grafts implantation (TSI).</p><p><b>METHODS</b>This retrospective review included 56 patients who underwent TSI during TEVAR for Stanford B aortic dissection from Jan 2012 to May 2013 in Beijing Anzhen hospital. There were 8 patients in acute phase (within 2 weeks from onset of symptoms), 11 patients in chronic phase (greater than 2 months following initial dissection) and 37 patients in subacute phase (between 2 weeks and 2 months from onset of symptoms). Infrarenal aorta was involved in 34 patients (60.7%) and suprarenal aorta involved in 22 patients (39.3%), the mean aortic lesion length was (226 ± 13)mm. Thoracic and abdominal aortic angiography was performed during operation to measure aortic diameters of proximal and distal landing zone, and the distance between them. The proximal stent-grafts were implanted in distal aorta to the origin of left subclavian artery with oversize rate of 10%-15% according to proximal landing zone according to procedural guideline. Then the distal newly customized large tapered stent-grafts were sequentially deployed according to the diameters of both the distal end of proximal stent and distal landing zone (aortic true lumen), and overlapping length of the two stent-grafts was more than 30 mm. Patients were followed-up at 3 months, 6 months, and yearly thereafter post operation.</p><p><b>RESULTS</b>TSI procedure was successful in all patients and 122 stent-grafts were implanted. The mean length of implanted stent-grafts was (197.6 ± 20.3)mm. The mean diameter taper span was (7.5 ± 1.8)mm with proximal oversize rate of (12.8 ± 3.4)% and distal oversize rate of (11.2 ± 4.1)%. The mean angle between the distal end of stent and aorta was (2.3 ± 1.3)°. The diameter of proximal and distal landing zone, and angle between the distal end of stent and aorta remained unchanged during follow up (mean (10.0 ± 4.0) months). The total thrombosis rate of the false lumen was 98.2% (55/56), thrombosis rate of stent segment was 82.1% (46/56) . Stent-related complications were observed in 2 patients (3.6%) , including acute spinal cord ischemia due to paraplegia (n = 1) and malposition of distal stent (n = 1).</p><p><b>CONCLUSIONS</b>Encouraging short-term outcomes are obtained from current personalized two stent-grafts implantation strategy for patients with Stanford B aortic dissection. Further prospective clinical studies are warranted to evaluate the long-term efficacy of this procedure.</p>
Full text:
Available
Index:
WPRIM (Western Pacific)
Main subject:
Aorta
/
Aortic Aneurysm
/
Subclavian Artery
/
Therapeutics
/
Thrombosis
/
Blood Vessel Prosthesis
/
Aortography
/
Tomography, X-Ray Computed
/
Stents
/
Acute Disease
Type of study:
Practice guideline
/
Observational study
Limits:
Humans
Language:
Chinese
Journal:
Chinese Journal of Cardiology
Year:
2015
Type:
Article
Similar
MEDLINE
...
LILACS
LIS