Your browser doesn't support javascript.
loading
Experimental study on effect of different chromatographic conditions on QAMS relative correlation factors and relative retention values / 中国中药杂志
Zhongguo Zhong Yao Za Zhi ; (24): 3264-3267, 2012.
Article in Zh | WPRIM | ID: wpr-308604
Responsible library: WPRO
ABSTRACT
<p><b>OBJECTIVE</b>To investigate the effect of different chromatographic conditions on QAMS relative correlation factors (RCF) and relative retention values (RT(R)).</p><p><b>METHOD</b>C18 columns were used with methyl alcohol-0.4% phosphoric acid water (85: 15) as the mobile phase. The detection wavelength was 254 nm, the column temperature was 30 degrees C, and the flow rate was 1.0 mL x min(-1). The five anthraquinones in Rhei Radix et Rhizoma were selected to be the objects of study. The RCF and RT(R) among aloe-emodin, rhein, chrysophanol, physcion and emodin were determined under different chromatographic conditions.</p><p><b>RESULT</b>Their RCFs showed no significant difference.</p><p><b>CONCLUSION</b>The RCFs among anthraquinones established by QAMS can be used as a constant in content determination of traditional Chinese medicines/patent traditional Chinese medicines.</p>
Subject(s)
Full text: 1 Index: WPRIM Main subject: Rheum / Chemistry / Chromatography, High Pressure Liquid / Methods Language: Zh Journal: Zhongguo Zhong Yao Za Zhi Year: 2012 Type: Article