Determination of polysorbate 80 in Reduning injection by HGPC-ELSD / 中国中药杂志
China Journal of Chinese Materia Medica
;
(24): 2915-2917, 2014.
Article
in Chinese
| WPRIM
| ID: wpr-327868
ABSTRACT
<p><b>OBJECTIVE</b>To establish the method for determining polysorbate 80 in Reduning injection by HPLC-ELSD, and to control the mass of polysorbate 80 in Reduning injection.</p><p><b>METHOD</b>It was performed by HGPC-ELSD with TOSHTSK-GEL G4000PWxl (7.8 mm x 300 mm, 10 μm). Water was used as mobile phase, the flow rate was 0.7 mL x min(-1), and the temperature was set at 30°C. The evaporated light scattering detector was adopted. The drift tube temperature was 55°C, and nitrogen was used as carrier gas, with the flow rate of 2.0 L x min(-1) and gain of 1.0.</p><p><b>RESULT</b>The calibration curve showed good linearity of polysorbate 80 in the test range from 1.01 to 15.20 g x L(-1) (r2 = 0.999 3). The recovery rate was 98.10% with RSD of 2.0%.</p><p><b>CONCLUSION</b>The method is simple, rapid, accurate and reliable and suitable for the determination of polysorbate 80 in Reduning injection.</p>