Your browser doesn't support javascript.
loading
Interferon-Gamma Release Assay is Not Appropriate for the Diagnosis of Active Tuberculosis in High-Burden Tuberculosis Settings: A Retrospective Multicenter Investigation / 中华医学杂志(英文版)
Chinese Medical Journal ; (24): 268-275, 2018.
Article in English | WPRIM | ID: wpr-342052
ABSTRACT
<p><b>BACKGROUND</b>Interferon-gamma release assay (IGRA) has been used in latent tuberculosis (TB) infection and TB diagnosis, but the results from different high TB-endemic countries are different. The aim of this study was to investigate the value of IGRA in the diagnosis of active pulmonary TB (PTB) in China.</p><p><b>METHODS</b>We conducted a large-scale retrospective multicenter investigation to further evaluate the role of IGRA in the diagnosis of active PTB in high TB-epidemic populations and the factors affecting the performance of the assay. All patients who underwent valid T-SPOT.TB assays from December 2012 to November 2015 in six large-scale specialized TB hospitals in China and met the study criteria were retrospectively evaluated. Patients were divided into three groups Group 1, sputum culture-positive PTB patients, confirmed by positive Mycobacterium tuberculosis sputum culture; Group 2, sputum culture-negative PTB patients; and Group 3, non-TB respiratory diseases. The medical records of all patients were collected. Chi-square tests and Fisher's exact test were used to compare categorical data. Multivariable logistic analyses were performed to evaluate the relationship between the results of T-SPOT in TB patients and other factors.</p><p><b>RESULTS</b>A total of 3082 patients for whom complete information was available were included in the investigation, including 905 sputum culture-positive PTB cases, 914 sputum culture-negative PTB cases, and 1263 non-TB respiratory disease cases. The positive rate of T-SPOT.TB was 93.3% in the culture-positive PTB group and 86.1% in the culture-negative PTB group. In the non-PTB group, the positive rate of T-SPOT.TB was 43.6%. The positive rate of T-SPOT.TB in the culture-positive PTB group was significantly higher than that in the culture-negative PTB group (χ2 = 25.118, P < 0.01), which in turn was significantly higher than that in the non-TB group (χ2 = 566.116, P < 0.01). The overall results were as follows sensitivity, 89.7%; specificity, 56.37%; positive predictive value, 74.75%; negative predictive value, 79.11%; and accuracy, 76.02%.</p><p><b>CONCLUSIONS</b>High false-positive rates of T-SPOT.TB assays in the non-TB group limit the usefulness as a single test to diagnose active TB in China. We highly recommend that IGRAs not be used for the diagnosis of active TB in high-burden TB settings.</p>
Full text: Available Index: WPRIM (Western Pacific) Type of study: Controlled clinical trial / Diagnostic study / Prognostic study Language: English Journal: Chinese Medical Journal Year: 2018 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Type of study: Controlled clinical trial / Diagnostic study / Prognostic study Language: English Journal: Chinese Medical Journal Year: 2018 Type: Article