Stability analysis of micropipette aspiration of cell by liquid drop modeling / 生物医学工程学杂志
Journal of Biomedical Engineering ; (6): 486-489, 2005.
Article in Chinese | WPRIM | ID: wpr-354268
ABSTRACT
A generally realized phenomenon in the suction experiment of cells is that if the aspiration pressure is larger than a certain threshold, cell flows continuously into the pipette. The point of the threshold aspiration pressure at which the cell can still be held in a stable equilibrium is called the critical point of aspiration. Here we represent a theoretical analysis of the equilibrium behavior and stability of cell by liquid drop model. In the method of analysis, the areal change due to a small movement deltaL of the portion of the membrane in pipette is given to the first approximation. The threshold pressure and the critical point are shown as simple formulas of the model parameters and inner relative radius of pipette. The results derived from formulas are consistent with rigorous ones by numerical computation in the approximate range.
Subject(s)
Full text: Available Index: WPRIM (Western Pacific) Main subject: Pressure / Suction / Cells / Models, Theoretical Language: Chinese Journal: Journal of Biomedical Engineering Year: 2005 Type: Article