Your browser doesn't support javascript.
loading
Early Experience with the 19-mm Medtronic Mosaic Porcine Bioprosthesis for Small Aortic Annuli / 日本心臓血管外科学会雑誌
Japanese Journal of Cardiovascular Surgery ; : 1-5, 2008.
Article in Japanese | WPRIM | ID: wpr-361779
ABSTRACT
A study was conducted to evaluate the clinical and hemodynamic performance of the 19-mm Medtronic Mosaic Valve (MMV) in the aortic position, which is a third-generation stented porcine bioprosthesis. Between 2003 and 2006, 9 patients underwent AVR using the 19-mm MMV. None of the patients were suitable for a 19-mm Perimount bioprosthetic valve due to having a small annulus and sinotubular junction. The patients included 3 men and 6 women with a mean age of 73.2±4.97 years and mean body surface area of 1.35±0.11m<sup>2</sup>. Preoperatively, 8 patients were in New York Heart Association class II and 1 was in class III. The reason for surgery was aortic stenosis in 8 patients and aortic regurgitation due to infective endocarditis in 1 patient. Four patients had chronic renal failure and were on hemodialysis, while 1 patient had Crohn's disease. Concomitant coronary artery bypass grafting was performed in 3 patients, and tricuspid valve annuloplasty was done in 1 patient. The follow-up period was 12.0±7.71 months. No deaths occurred, but there was 1 cerebral infarction. Postoperatively, the peak pressure gradient decreased from 81.3±32.7 to 40.3±16.3mmHg (<i>p</i><0.01). The mean pressure gradient also decreased significantly from 48.8±11.6mmHg to 23.9±9.32mmHg (<i>p</i><0.01). Left ventricular end-diastolic diameter was 47.9±3.82mm preoperatively and 45.1±7.53mm postoperatively, showing no significant change. The left ventricular mass index also improved from 217.3±46.9 to 160±54.9g/m<sup>2</sup> (<i>p</i><0.05). The ejection fraction was 72.0±8.93% preoperatively and 67.6±6.37% postoperatively, showing no difference. Although the postoperative indexed effective orifice area (EOAI) was 0.90±0.11cm<sup>2</sup>/m<sup>2</sup>, mild patient-prosthesis mismatch (EOAI 0.77cm<sup>2</sup>/m<sup>2</sup>) was noted in 1 patient. In conclusion, the early clinical and hemodynamic performance of the 19-mm MMV in small elderly patients was acceptable.
Full text: Available Index: WPRIM (Western Pacific) Language: Japanese Journal: Japanese Journal of Cardiovascular Surgery Year: 2008 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Language: Japanese Journal: Japanese Journal of Cardiovascular Surgery Year: 2008 Type: Article