Your browser doesn't support javascript.
loading
A Study on the Improvement of Digital Periapical Images using Image Interpolation Methods / 대한구강악안면방사선학회지
Journal of Korean Academy of Oral and Maxillofacial Radiology ; : 387-414, 1998.
Article in Korean | WPRIM | ID: wpr-36456
ABSTRACT
Image resampling is of particular interest in digital radiology. When resampling an image to a new set of coordinate, there appears blocking artifacts and image changes. To enhance image quality, interpolation algorithms have been used. Resampling is used to increase the number of points in an image to improve its appearance for display. The process of interpolation is fitting a continuous function to the discrete points in the digital image. The purpose of this study was to determine the effects of the seven interpolation functions when image resampling in digital periapical images. The images were obtained by Digora, CDR and scanning of Ektaspeed plus periapical radiograms on the dry skull and human subject. The subjects were exposed to intraoral X-ray machine at 60kVp and 70 kVp with exposure time varying between 0.01 and 0.50 second. To determine which interpolation method would provide the better image, seven functions were compared ; (1) nearest neighbor (2) linear (3) non-linear (4) facet model (5) cubic convolution (6) cubic spline (7) gray segment expansion. And resampled images were compared in terms of SNR(Signal to Noise Ratio) and MTF(Modulation Transfer Function) coefficient value. The obtained results were as follows ; 1. The highest SNR value(75.96dB) was obtained with cubic convolution method and the lowest SNR value(72.44dB) was obtained with facet model method among seven interpolation methods. 2. There were significant differences of SNR values among CDR, Digora and film scan(p0.05). 4. There were significant differences of MTF coefficient values between linear interpolation method and the other six interpolation methods(p<0.05). 5. The speed of computation time was the fastest with nearest neighbor method and the slowest with non-linear method. 6. The better image was obtained with cubic convolution, cubic spline and gray segment method in ROC analysis. 7. The better sharpness of edge was obtained with gray segment expansion method among seven interpolation methods.
Subject(s)

Full text: Available Index: WPRIM (Western Pacific) Main subject: Skull / ROC Curve / Artifacts / Radiography, Dental, Digital / Noise Type of study: Prognostic study Limits: Humans Language: Korean Journal: Journal of Korean Academy of Oral and Maxillofacial Radiology Year: 1998 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Main subject: Skull / ROC Curve / Artifacts / Radiography, Dental, Digital / Noise Type of study: Prognostic study Limits: Humans Language: Korean Journal: Journal of Korean Academy of Oral and Maxillofacial Radiology Year: 1998 Type: Article