No case of graft replacement for abdominal aortic aneurysm in a case of congenital deficiency of coagulation factor X III has yet been reported. Recently we performed graft replacement of 66-year-old man with congenital deficiency of coagulation factor X III. Concentrated factor X III separated from human placenta (Fibrogamin<sup>®</sup>) was used during, before and after the operation. We measured factor X III activity, and when the activity was so low that replacement therapy was necessary, we administered Fibrogamin immediately. We maintained coagulation factor X III activity at over 70%. No adverse reaction of factor X III replacement therapy was observed. The postoperative course was uneventful and the patient did not have delayed wound healing.