Mechanical Properties of F Plate in Intraarticular Calcaneal Fractures
Journal of the Korean Fracture Society ; : 167-172, 2004.
Article in Korean | WPRIM | ID: wpr-36969
ABSTRACT

PURPOSE:

We evaluated the mechanical properties of F plate fixation comparing with Y plate and a screw fixation for the intraarticular calcaneal fractures using synthetic bones. MATERIALS AND

METHODS:

Using 12 synthetic calcaneal bones, newly designed F plate was compared with the Y-plate, most commonly used, regarding the change of Bohler angle and the displacement of the thalamic fragments of the calcaneus after axial compressive loading by Instron 6022.

RESULTS:

Y plate fixation lost 8degrees of Bohler angle in average after axial compressive load and 2.6degrees in F plate fixation. Thalamic fragments were displaced 1.72 mm in average in Y plate fixation group and 0.73 mm in F plate fixation group.

CONCLUSION:

F plate offered more firm fixation than Y plate in the intraarticular calcaneal fracture in the aspect of maintaining the Bohler angle and preventing displacement of the thalamic fragments of calcaneus against axial compressive loading.
Subject(s)

Full text: Available Index: WPRIM (Western Pacific) Main subject: Calcaneus / Intra-Articular Fractures Language: Korean Journal: Journal of the Korean Fracture Society Year: 2004 Type: Article