A Case of Hemolytic Anemia Caused by a Kinked Graft after Operation for Aortic Dissection / 日本心臓血管外科学会雑誌
Japanese Journal of Cardiovascular Surgery
;
: 275-278, 2015.
Article
in Japanese
| WPRIM
| ID: wpr-377172
ABSTRACT
A 62-year-old woman was referred to our hospital for treatment of hemolytic anemia 10 years after total arch replacement for acute aortic dissection. The cause of hemolysis was confirmed to be mechanical damage of red blood cells at the kinked graft. Because aortic valve regurgitation and occlusion of the left subclavian artery were also found, resection of the kinked graft, aortic valve replacement and reconstruction of the left subclavian artery were carried out concomitantly at reoperation. Her postoperative course was uneventful, and hemolysis resolved soon after the operation.