Role of PCO2 and pH measurements sampled from the right atrial cavity via the central venous catheter in open heart surgery
Journal of Medical Research
;
: 46-48, 2005.
Article
in Vietnamese
| WPRIM
| ID: wpr-3787
ABSTRACT
CO2 and W produced in tissus come into venous blood. Can PCO2 and pH sampled from the right atrial blood via a central venous catether approriately replace the arterial PCO2 and pH in open hear surgery? Objectives:
To evaluate the correlation and the agreement of PCO2 and of pH between the arterial and venous right atrial blood.Methods:
Cross-over study with matched comparision, calculation of paired t test, coefficient of correlation r (Pearson), agreement (Bland-Altman).Results:
Arterial-venous right atrial PC02 gradient-5.68 (+/-2.44), r = 0.92 and narrow agreement. Arterial-venous right atrial pH gradient 0.04 (+/-0.02), r = 0.94 and narrow agreement.Conclusion:
PCO2 and pH of the right atrial blood can safely replace the arterial PCO2 and pH in cardiac anesthesia and intensive care.
Full text:
Available
Index:
WPRIM (Western Pacific)
Main subject:
Thoracic Surgery
/
Catheterization
/
Atrial Function, Right
/
Hydrogen-Ion Concentration
Type of study:
Controlled clinical trial
Language:
Vietnamese
Journal:
Journal of Medical Research
Year:
2005
Type:
Article
Similar
MEDLINE
...
LILACS
LIS