Your browser doesn't support javascript.
loading
Establishment of a off-pump leukocyte depletion method in canines / 中华麻醉学杂志
Chinese Journal of Anesthesiology ; (12): 1005-1007, 2009.
Article in Chinese | WPRIM | ID: wpr-391708
ABSTRACT
Objective To establish a off-pump leukocyte depletion method in canines.Methods Twenty-one healthy adult mongrel dogs of both sexes, weighing 10-12 kg, were randomized into 2 groups control group (group C, n = 9) and leukocyte depletion group (group LD, n = 12) . An extracorporeal leukocyte filtration end was constructed by aseptic puncture of the bilateral external jugular veins via a blood transfusion line and the leukocyte filter for extracorporeal leukocyte depletion. In group LD, blood was filtered with a MP-300 blood line and a SQ40S leucocyte depletion filter one end placed in the right external jugular vein (artery end) and the other end placed in the left external jugular vein (venous end). After heparin anticoagulation, a MP-300 blood line pump was used as the power. Blood was filtered at a rate of 75 ml/min and it was maintained for 60 min. The artery end was then closed, normal saline injected into the closed circuit, the remaining blood pumped into the body, and then the venous end closed. In group C, aseptic puncture of the bilateral external jugular veins was performed. Arterial blood samples were taken immediately before leukodepletion (baseline, T_0 ) , at 10, 20, 30, 40, 50 and 60 min of leukodepletion (T_(1-6) , depletion period), and at 10, 20, 30, 40, 50, 60, 120, 180 and 270 min after leukodepletion (T_(7-15) , recovery period) for determination of blood routine. MAP, HR, RBC.Plt and body temperature were recorded at T_0 , T_6 , T_(12) and T_(15) . Results There were no significant difference in MAP and RBC between the two groups ( P > 0.05 ) . HR, body temperature, and Plt were significantly lower in group LD than in group C (P < 0.05) .The leukocyte concentration was lower during depletion period in group LD than in group C ( P < 0.05) , while there was no significant difference in leukocyte concentration during recovery period between the two groups (P > 0.05 ). Conclusion The off-pump leukocyte depletion method is successfully established and has exact efficacy with less adverse effects in this study.

Full text: Available Index: WPRIM (Western Pacific) Type of study: Controlled clinical trial Language: Chinese Journal: Chinese Journal of Anesthesiology Year: 2009 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Type of study: Controlled clinical trial Language: Chinese Journal: Chinese Journal of Anesthesiology Year: 2009 Type: Article