Establishment of hyperinsulinemic euglycemic clamp technique and the reference value of insulin sensitivity index in Chinese / 中华临床营养杂志
Chinese Journal of Clinical Nutrition
;
(6): 17-20, 2009.
Article
in Chinese
| WPRIM
| ID: wpr-393011
ABSTRACT
Objective To establish the technique of hyperinsulinemic euglycemic clamp and to study the reference value of insulin sensitivity index in healthy Chinese. Methods According to the feedback mathematical model developed by DeFronzo, the technique of hyperinsulinemic euglycemic clamp was used in 90 healthy Chi- nese [ malefemale =71 = 19; age; (28. 3±6. 1) years; body mass index (20. 9±1.5) kg/m2 ] to study die glu-cose metabolized rate. Blood samples were obtained at timed intervals in the fasting state and during the clamp for the measurement of glucose, insulin and C peptide. Results During the clamp tests, the blood glucose levels were con-trolled within 10% of target value. The coefficient of variation of glucose levels was 3. 8% 0.1%. In the steady state, the insulin sensitivity index (glucose metabolized rate, M value ) was (7.78±2.30) mg· kg-1 min-1, which was distributed normally. The lowest quartile of M value was 6. 286 mg·kg -1 min-1'. The coefficient of variation of M value was 9.4%±2.8%. Conclusion The technique of hyperinsulinemic euglycemic clamp and the reference value of insulin sensitivity index in healthy Chinese are successfully established in our center.
Full text:
Available
Index:
WPRIM (Western Pacific)
Type of study:
Diagnostic study
Language:
Chinese
Journal:
Chinese Journal of Clinical Nutrition
Year:
2009
Type:
Article
Similar
MEDLINE
...
LILACS
LIS